ABSTRACT

@#In this paper, micellar electrokinetic chromatography (MEKC) with glucose-β-cyclodextrin (Glu-β-CD) as chiral selector and ionic liquid surfactant N-butyl-N-methyl pyrrolidine lauryl sulfate ([C4MP] [C12SO4]) micelles formed at low pH as a pseudo stationary phase was applied for the chiral separation of four acidic drugs naproxen,warfarin, ketoprofen and ibuprofen.Under the same conditions,significantly improved separation of tested drug enantiomers was achieved with the MEKC system based on [C4MP][C12SO4] compared with the system based on the conventional surfactant sodium dodecyl sulfate (SDS).Several primary parameters affecting enantioseparation such as type and proportion of organic modifier, concentration and pH of the running buffer, concentration of chiral selector,concentration of ionic liquid surfactant and applied voltage were systematically investigated.

2.
China Journal of Chinese Materia Medica ; (24): 5832-5838, 2021.
Article in Chinese | WPRIM | ID: wpr-921703

ABSTRACT

The present study determined five saponins in Xuesaitong Dropping Pills(XDP) by micellar electrokinetic chromatography(MEKC), and evaluated between-batch consistency by MEKC fingerprints and similarity analysis. A background buffer was composed of 20 mmol·L~(-1) sodium tetraborate-20 mmol·L~(-1) boric acid solution(pH 8.5), 55 mmol·L~(-1) sodium dodecyl sulfate(SDS), 23 mmol·L~(-1) β-cyclodextrin, and 13% isopropyl alcohol. All separations were performed at 25 ℃,20 kV and the detection wavelength was set at 203 nm. The separation channel was a fused silica capillary with a dimension of 75 μm I.D. and a total length of 50.2 cm(effective length of 40.0 cm). The contents of notoginsenoside R_1, and ginsenosides Rg_1, Re, Rb_1, Rd were determined with their quality control ranges set. The fingerprints of XDP were established and the between-batch consistency was evaluated by similarity analysis. The contents of five saponins from the 19 batches of XDP were stable in the fixed ranges. Statistical analysis was carried out on the results of multiple batches of samples, and the specific quality control ranges were recommended as follows: notoginsenoside R_1 21.92-34.16 mg·g~(-1), ginsenosides Rg_1 83.54-131.78 mg·g~(-1), ginsenosides Re 13.58-19.82 mg·g~(-1), ginsenosides Rb_1 89.40-129.90 mg·g~(-1), and ginsenosides Rd 22.34-35.67 mg·g~(-1). Eleven characteristic peaks were identified in the fingerprints. Five peaks, notoginsenoside R_1 and ginsenosides Rg_1, Re, Rb_1, Rd, were identified with reference standards. The similarities of the 19 batches of samples were all above 0.988, indicating good between-batch consistency. This method is green and simple, and can be used for the quantitative determination and quality evaluation of XDP. It can also provide references for the quality control of other Chinese medicinal dripping pills.


Subject(s)
Chromatography, Micellar Electrokinetic Capillary , Drugs, Chinese Herbal , Micelles , Quality Control , Saponins
3.
São Paulo; s.n; s.n; 2018. 88 p. graf, tab.
Thesis in Portuguese | LILACS | ID: biblio-980422

ABSTRACT

Estudos envolvendo os glicocorticoides merecem destaque devido a serem hormônios responsáveis pela transferência de informações e instruções às células, desta forma regulando o metabolismo, desenvolvimento, crescimento, função imune e também auxiliam no controle das funções tanto reprodutivas quanto tecidual. Estes também são sintetizados e amplamente utilizados com finalidade terapêutica processos alérgicos, tratamento de doenças autoimunes, em transplantes no pré-operatório e/ou pós-operatório-, devido a sua eficiente ação como imunossupressores e anti-inflamatórios. Os dois primeiros capítulos deste trabalho exibem uma revisão da literatura com foco em considerações gerais sobre os glicocorticoides, metodologias empregadas na análise destes hormônios e fundamentos da eletroforese capilar. Na sequência, o quarto capitulo, mostra a otimização da separação de 17 glicocorticoides utilizando cromatografia eletrocinética micelar devido a alto grau hidrofóbico dos analitos. Para tal, a composição do eletrólito consistiu em 20mM de tetraborato de sódio (pH=9.3) e 30 mM de dodecil sulfato de sódio (como surfactante), e a interação soluto-micela e, portanto, retenção do soluto, foi manipulada com a adição (volume/volume) de solventes orgânicos na composição de até 20% acetonitrila (ACN), 20% etanol (EtOH) e 1% tetrahidrofurano (THF), a qual se baseia num modelo de desenho de misturas (totalizando dez diferentes eletrólitos), e através desta abordagem um ótimo de separação foi obtido (13,3% EtOH, 3,3% ACN e 0,17% THF). A melhor condição de separação foi testada qualitativamente numa amostra de urina de um voluntário que faz uso contínuo de prednisona como terapia corticoidal. As misturas de solventes estudadas neste trabalho afetam a solubilidade dos hormônios na fase aquosa e a estrutura micelar também sofre grande impacto,principalmente na camada de solvatação. O quarto capítulo busca racionalizar tais efeitos através da obtenção de descritores, e as informações contidas nos descritores hidrofóbicos e hidrofílicos são sempre relevantes e contribuem nas correlações encontradas. Obteve três grupos de comportamento distinto, onde a capacidade doadora e aceptora de prótons para a realização de ligações de hidrogênios foram as interações consideradas as mais relevantes para o comportamento observado da separação. E o capítulo final, apresenta possibilidades de aproveitamento no controle de qualidade na indústria farmacêutica, métodos baseados na injeção e tensão inversas foram propostos a fim de ganho de tempo de análise (máximo de 5 minutos), estes foram validados seguindo o protocolo preconizado pela ANVISA (Agência Nacional de Vigilância Sanitária) nos parâmetros: precisão, exatidão, seletividade, linearidade, limites de detecção e quantificação e robustez; e aplicados na quantificação de quatro (diferentes formulações comerciais contendo glicocorticoides (prednisona 20 mg, betametasona 4 mg, furoato de mometasona 200 mcg e dipropionato de beclometasona 200 mcg)


Studies involving glucocorticoids deserve to be highlighted because they are hormones responsible for the transfer of information and instructions to cells, thus regulating metabolism, development, growth, immune function and also assist in the control of both reproductive and tissue functions. These are also synthesized and widely used for therapeutic purposes - allergic processes, treatment of autoimmune diseases, in preoperative and/or postoperative transplants - due to their efficient action as immunosuppressants and anti-inflammatories. The first two chapters of this paper present a review of the literature focusing on general considerations about glucocorticoids, methodologies used in the analysis of these hormones and fundamentals of capillary electrophoresis. Subsequently, the fourth chapter shows the optimization of the separation of 17 glucocorticoids using micellar electrokinetic chromatography due to the high hydrophobic degree of the analytes. To this end, the electrolyte composition consisted of 20 mM sodium tetraborate (pH = 9.3) and 30 mM sodium dodecyl sulfate (as a surfactant), and the solute-micelle interaction and therefore solute retention was manipulated with organic solvent in the composition of up to 20% acetonitrile (ACN), 20% ethanol (EtOH) and 1% tetrahydrofuran (THF), which is based on a mixture design model (totaling ten different electrolytes), and through this approach an optimal separation was obtained (13.3% EtOH, 3.3% ACN and 0.17% THF). The best separation condition was qualitatively tested in a urine sample from a volunteer who makes continuous use of prednisone as corticosteroid therapy. The solvent mixtures studied in this work affect the solubility of the hormones in the aqueous phase and the micellar structure also has a great impact, especially on the solvation layer. The fourth chapter seeks to rationalize these effects by obtainingdescriptors, and the information contained in the hydrophobic and hydrophilic descriptors is always relevant and contributes to the correlations found. It obtained three groups of distinct behavior, where the donor and acceptor capacity of protons for the realization of hydrogen bonds were the interactions considered the most relevant for the observed behavior of the separation. And the final chapter presents possibilities of use in quality control in the pharmaceutical industry, methods based on injection and reverse voltage were proposed in order to gain analysis time (maximum of 5 minutes), these were validated following the protocol recommended by ANVISA (Brazilian National Agency of Sanitary Surveillance) in the parameters: precision, accuracy, selectivity, linearity, limits of detection and quantification and robustness; and applied in the quantification of four different commercial formulations containing glucocorticoids (prednisone 20 mg, betamethasone 4 mg, mometasone furoate 200 mcg and beclomethasone dipropionate 200 mcg)


Subject(s)
Electrophoresis, Capillary , Drug Compounding , Glucocorticoids/analysis , Steroids , Chromatography, Micellar Electrokinetic Capillary/methods
4.
Chinese Herbal Medicines ; (4): 53-57, 2015.
Article in Chinese | WPRIM | ID: wpr-842318

ABSTRACT

Objective: To establish a rapid method for detecting acetylbritannilactone (ABL) by online sweeping-micellar electrokinetic chromatography (MEKC) and to elevate the sensitivity of the detection. Methods: The combination of online sweeping technique with MEKC was used to determine the content of ABL in the extract of Inula britannica in plasma of rats. Results: ABL was completely separated within 15 min in running buffer and sample buffer. The optimal conditions were as follows: on uncoated fused quartz silica capillary, with separation voltage of 23 kV, capillary temperature of 25 °C, and detection wavelength of 195 nm. The regression equations revealed good linear relationships between the peak area and concentration of ABL (r = 0.998), with the detection limits of 0.005-0.15 mg/mL. The relative standard deviations of migration time and peak areas for intra- and inter-batch were < 2.45% and < 2.26%, respectively. The recovery rate of this method was 96.3%-97.2%. Conclusion: This method provides some advantages in separation speed, testing sensitivity, and operating convenience, with low sample and reagent consumption. The online sweeping-MEKC is an effective method for pharmacokinetic study and analysis on tracing biological samples. © 2014 Tianjin Press of Chinese Herbal Medicines.

5.
Journal of Pharmaceutical Analysis ; (6): 213-222, 2015.
Article in Chinese | WPRIM | ID: wpr-672174

ABSTRACT

Bioanalytical methods are widely used for quantitative estimation of drugs and their metabolites in physiological matrices. These methods could be applied to studies in areas of human clinical pharma-cology and toxicology. The major bioanalytical services are method development, method validation and sample analysis (method application). Various methods such as GC, LC-MS/MS, HPLC, HPTLC, micellar electrokinetic chromatography, and UFLC have been used in laboratories for the qualitative and quan-titative analysis of carbamazepine in biological samples throughout all phases of clinical research and quality control. The article incorporates various reported methods developed to help analysts in choosing crucial parameters for new method development of carbamazepine and its derivatives and also enu-merates metabolites, and impurities reported so far.